Taking Your Diagnosis Through To The End - What Blew The Fuse? autos: I was shopping around for a scan tool, taking my time and reading everything I could get my hands on. I've been watching a bunch of your PicoScope videos and I've decided to change my direction. Our shop has an Autel but nobody has a scope. In fact when I mentioned that I am looking for one, i got the ol well i been turning wrenches 20 years and I never needed one of those. Well sure, you can use decades of experience to give you a more accurate throwing arm as you play Parts Darts. But I want to be able to prove what I think may be the cause of a problem, plus the real experts use scopes. We may not need it every day but think of the TV show House MD. He was the guy who got cases handed to him after 5 other professionals could not figure out the problem. Anyway, now I'm shopping around for a used Pico on ebay. I already have a good hand-me-down win7 i5 8gb ddr3 laptop which, once I cleared off all the junk, runs very smooth.
Date: 2020-08-05

Comments and reviews: 9


Eric, The only thing I did not see you verify was the grounds. Now I know you and others might say they are good because the fans worked, but we both know that is not 100% accurate. Just like the fans didn't blow the fuse while you had it running in the bay, so they must be fine.
Not saying the grounds were at fault, but if they were corroded, they would add resistance to the circuit and up the amp draw. I agree the one fan was fersnickered, but I didn't see you verify the ground circuit. We both live in rustophukinwonderful areas and that should have been done. I know because I have had it bite me in the past.

reply

You said you were not sure why you made this video, well I could see right at the start that this was an issue that needed to be told! Now I digress for a moment, you are such a humanitarian, I know of no shop that would go through what you do to save someone some cash. With that said, you id a great service showing people why you cannot just replace a fuse and walk away. In my mind as was yours, there would always be the question of why did the fuses blow? There is always a reason.
reply

Eric, I loved this video when it was new, just watched again. It is awesome to find how much you can discover about how it is working while it is working. I watched Scanner Danner do the same with a fuel pump motor, even calculating the pump's rpm by the time base on a pulse width modulated pump. You do great work building the integrity of your trade. Thank you.
reply

Your tagline If I can do it. isn't true any more. You do a better job of diagnosis and have a better understanding of what is happening than many professional mechanics. Without that understanding being able to take things apart and re-assemble them while following a manufacturer's procedure is not much more effective than throwing parts at a problem.
reply

Eric, you my friend are what they refer to in this business as a, REPUTABLE MECHANIC. I'd let you work on my car, with my family in it! Lol. Great work and with your integrity, you are guaranteed to always have full bays and a full cash drawer! Take care. Jpol. Remember. more old school diagnosis. Please and Thank you.
reply

This is a few years old and I am a bit late, but if you ever suspect an intermittent short to ground you can disconnect both side of the wire and put a megohmeter on it and see if the insulation is compromised. Putting 1000v on it will cause voltage to jump any short gaps and that shows up on the meter.
reply

Outstanding video, I'm glad I didn't miss this one! And, hurray for old style junk yards, it's nice to see you found one. My junk yards locally won't even let me walk through their yard, their insurance won't permit it. Mostly they trash anything they can't sell right away.
reply

Eric I've been on a roll rewatching and catching up on your videos, but I really loved this one, because you are teaching a very valuable lesson on finding out the why. excellent!
Also, thanks for sharing the waveforms on the before and after. very valuable for learnin'!

reply

Prior to scope testing, I had an older Sears Craftsman combination Voltage/Current (up to 100 Amps using a shunt, Dwell (for contact points and the old GM Mixture Control Solenoid) and RPM. The Current got the most use, and although it was an analog meter. IT WORKED!
reply