Chiller faults - troubleshooting
video description
Date: 2023-11-17
Related videos
Comments and reviews: 12
SHASHI
Trane CDHG water cooled chiller
Refrigerant- R123
Problem- chiller not going load more than 80% and not achieve set temp, we changed leaving water sensor, saturation temp sensor, refrigerant charged, manually igv open, water flow is normal but still problem not solved, please suggest me
reply
Trane CDHG water cooled chiller
Refrigerant- R123
Problem- chiller not going load more than 80% and not achieve set temp, we changed leaving water sensor, saturation temp sensor, refrigerant charged, manually igv open, water flow is normal but still problem not solved, please suggest me
reply
Eng
Hello guys. i want your help in this i am still newbie with hvac system and in the place where i work there is swas chiller. From time to time cause high pressure alarm. what do you advice me to inspect which part. i inspected condenser filter and fan motor. plz i need your help with that. thx
reply
Hello guys. i want your help in this i am still newbie with hvac system and in the place where i work there is swas chiller. From time to time cause high pressure alarm. what do you advice me to inspect which part. i inspected condenser filter and fan motor. plz i need your help with that. thx
reply
education
Hey Paul, how are ya? I was wondering if you could make another video about troubleshooting? Common faults with AC units, chillers, heat pumps? I would like a video like this, it was helpful for me. / Lineus
reply
Hey Paul, how are ya? I was wondering if you could make another video about troubleshooting? Common faults with AC units, chillers, heat pumps? I would like a video like this, it was helpful for me. / Lineus
reply
Akash
ln my lab chiller is showing 50degree centigrade temperature of collent since actual measured temperature of collent is 20 degree.
please suggest me a proper solution of this issue?
reply
ln my lab chiller is showing 50degree centigrade temperature of collent since actual measured temperature of collent is 20 degree.
please suggest me a proper solution of this issue?
reply
Miguel
Hi Im having trouble with a bitzer compressor i replaced oil pressure switch and now compressor wont come out of pump down or go into refrigeration mode any suggestion on wat to check
reply
Hi Im having trouble with a bitzer compressor i replaced oil pressure switch and now compressor wont come out of pump down or go into refrigeration mode any suggestion on wat to check
reply
Danel
my client's chiller circuit board burn cause by lizard. another one is fan and compressor not running. the control shows E 26 was error. ps: im new to it
reply
my client's chiller circuit board burn cause by lizard. another one is fan and compressor not running. the control shows E 26 was error. ps: im new to it
reply
Franklin
How can I troubleshoot if one cooling tower, one condenser water pump and one chiller water pump are not working. help me please?
reply
How can I troubleshoot if one cooling tower, one condenser water pump and one chiller water pump are not working. help me please?
reply
ejaz
Hi I have chiller 30ax carrier
I have problem compressor started but condenser fan not getting started
Pls advise me
reply
Hi I have chiller 30ax carrier
I have problem compressor started but condenser fan not getting started
Pls advise me
reply
Afzal
sir make a vedio on how calculate usgpm of water. and selection of pipes in chilled water cycle and condenser water cycle
reply
sir make a vedio on how calculate usgpm of water. and selection of pipes in chilled water cycle and condenser water cycle
reply
Sonu
When chiller running igv not properly open but hot bypass line open around 70% open so chiller not working properly
reply
When chiller running igv not properly open but hot bypass line open around 70% open so chiller not working properly
reply
Masterchef
Thanks for sharing knowledge. Could you do a video on ahri standard for rating chiller performance data.
reply
Thanks for sharing knowledge. Could you do a video on ahri standard for rating chiller performance data.
reply
Muhammad
can i connect evaporator inlet from cooling tower instead of water tank will it effect? thanks in advance
reply
can i connect evaporator inlet from cooling tower instead of water tank will it effect? thanks in advance
reply